Koolance ERM-3K4U5 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Hardware Koolance ERM-3K4U5. Koolance ERM-3K4U5 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 29
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Protected by U.S. Patents 6,664,627; 6,313,990; 6,234,240; 5,731,954
Other Technology Pending U.S. & World-Wide Patents
Superior Liquid Cooling Systems
®
English v1.00
ERM-3K4U
Users Manual
ERM-3K4U
Users Manual
Zobrazit stránku 0
1 2 3 4 5 6 ... 28 29

Shrnutí obsahu

Strany 1 - User’s Manual

Protected by U.S. Patents 6,664,627; 6,313,990; 6,234,240; 5,731,954Other Technology Pending U.S. & World-Wide PatentsSuperior Liquid Cooling Sys

Strany 2 - User Manual

5User ManualSystem SettingsBy default, the ERM-3K4U automatically adjusts fan speeds based on the liquid temperature inside the reservoir. For actual

Strany 3

6 IntroductionLED Display - Alarm SettingsBy default, the Koolance audio alarm will sound if the primary sensor reaches 55ºC (131ºF). When the syst

Strany 4 - Table of Contents

7User ManualLED Display - RotatingThe front LED display of the ERM-3K4U can be rotated horizontally and used as a 4U rack-mounted chassis, or vertical

Strany 5 - Required Tools

8 Connecting ERM-3K4U SystemsChapter2Connecting ERM-3K4U Systems

Strany 6 - Chapter1

9User ManualPower ConnectionThe ERM-3K4U has a primary power connection on the rear side. This will accept either 120V/60Hz or 220V/50Hz inputs. The m

Strany 7

10Depending on the cooling blocks (“coolers”) in your Koolance system and tubing sizes, they may be connected in series, parallel, or a mixture of bot

Strany 8

11User ManualParallel TubingKoolance coolers which are 6mm (1/4”) can still be effectively used in larger diameter systems. Using a parallel tubing c

Strany 9 - ERM-3K4U System Diagram

12Each tubing connection uses a threaded compression fi tting (“hose screw”) to keep it secure. To connect these components:Connecting HosesThread a ho

Strany 10 - LED Display Panel

13User ManualDisconnecting HosesHoses are designed to snug fi rmly around the nozzle. If you need to remove a hose for any reason, it may not pull off

Strany 11

14Hose LengthsBefore installing your liquid coolers, appropriate lengths of tubing must be cut to connect each device. It may be easier to temporarily

Strany 12

iUser ManualThis User Manual is updated regularly. Please be sure to check our support page for a newer version of this guide: www.koolance.com/suppor

Strany 13 - Chapter2

15User ManualContinue connecting all of your coolers in the system until there are no longer any open tube ends.Liquid CoolersYou should now install t

Strany 14 - Pump Connections

16Chapter3Filling & MaintenanceFilling & MaintenanceWARNING: The ERM-3K4U pumps can not be run “dry” for any period of time. Never power-on th

Strany 15

17User ManualTesting & FillingOnce all of the coolers have been con-nected, the system can be fi lled with coolant. The refi ll plug is located on

Strany 16

18Allow the pump to run for about 1-5 minutes. When fi ltration has ended, the liquid “bubbling” noise should stop. The reservoir level will typically

Strany 17 - Connecting Hoses

19User ManualFor preventative maintenance, Koolance recommends replacing the liquid coolant every 2 years. A Koolance “drain valve” (sold separately)

Strany 18 - Disconnecting Hoses

20We hope your Koolance system will provide you with years of reliable cooling performance. To help avoid unnecessary RMA issues, we have prepared thi

Strany 19 - Hose Lengths

21User Manualbe malfunctioning. Please visit our support web page for more information.Verify that the pump is operating (see Troubleshooting #1), and

Strany 20 - Liquid Coolers

228. The LED Display Panel shows 5 - 0 (“S - 0”) or 5 - 5 (“S - S”)...Your Koolance LED display may specify if there is a problem with the cooling uni

Strany 21 - Chapter3

23User ManualLimited WarrantyDisclaimerKoolance Incorporated (“Koolance”) warrants each new Koolance liquid-cooled system (“the system”), against defe

Strany 22 - Testing & Filling

www.koolance.comISO 9001Printed in Korea

Strany 23

iiWARNING: The Koolance liquid & coolant pack contain chemicals which may be harmful or fatal if swallowed. KEEP THIS AND ALL DANGEROUS CHEMICALS

Strany 24

iiiUser ManualTable of ContentsIntroduction 1ERM-3K4U System Diagram ... 4LED D

Strany 25 - Troubleshooting

iv ERM-3K4U Series Systems: - ATX power jumper wire - liquid coolant mixture with funnel - liquid tubing - user manual - rear shutoff quick disc

Strany 26

1User ManualChapter1Introduction

Strany 27

2 Congratulations on your purchase of a Koolance system!As the most sophisticated product of its kind, Koolance offers many unique features found now

Strany 28 - Disclaimer

3User ManualEvery Koolance system includes built-in hardware safety features. Our proprietary power control board constantly monitors liquid temperatu

Strany 29 - Printed in Korea

4 IntroductionERM-3K4U System DiagramReservoirRear Radiator Cooling FansRadiator(Primary Heat Exchanger)*Inlet / Outlet Nozzles& Power Switch f

Příbuzné modely ERM-3K4U1

Komentáře k této Příručce

Žádné komentáře